Skip to Main Content
logo
Search
Recently Searched
    • Store Image Profile Picture Image
      • Edit Page
      • MyNEMA
      • Settings
      • Log Out
      Store Image Login
      • NEMA
      • Standards
      • Fittings for Polyvinyl Chloride (PVC) Plastic Utilities Duct for Underground Installation
        • Store Icon White Profile Picture Image
          • Edit Page
          • MyNEMA
          • Settings
          • Log Out
          Store Image Login
      • About
        • About NEMA
        • Careers
        • NEMA Leadership
        • Board of Governors
        • Programs & Events

          NEMA Year in Review

      • Membership
        • NEMA Councils
        • Product Sections
        • Membership Directory
        • Advocacy
          • Action Center
          • Cybersecurity Council Government Relations Subcommittee
          • Healthcare
          • Buy America(n)
          • NEMA Mexico
          • Storm Reconstruction Toolkit
          • Contact Us
          • Energy Policy
          • Infrastructure
          • Economic Impact
          • NEMA Political Action Committee (PAC)
          • Send me the latest news!
          • Regulatory Comments
          • Environmental Stewardship
          • The Energy Transition
          • International Trade
          • Policy Trackers

            Read about NEMA Advocacy Efforts in Washington Watch

        • Intelligence
          • NEMA’s Guide to the Electroindustry
          • Economic Impact
          • electroindustry Business Conditions Index
          • Send me the latest news!
          • Lamp Indices

            Get the Latest Electroindustry Business Conditions Indices

        • Standards
          • All Standards
          • Code Alerts
          • Patent Disclosure Policy
          • Standards Store
          • Send me the latest news!
          • All Standards by Product
          • International Activities
          • Technical Field Representative Program
          • White Papers
          • About NEMA Standards
          • Publicaciones en Español
          • Technical Services
          • Why Standards
          • News & Trends
            • Blog
            • Awards
            • Podcast
            • Advertise with NEMA
            • NEMA News
            • Send me the latest news!
            • DICOM
            • MITA
            • More
              Intelligence
              Standards
              News & Trends
              DICOM
              MITA

            Data saved successfully.

            Data saved successfully.

             
            1. NEMA
            2. Standards
            3. Fittings for Polyvinyl Chloride (PVC) Plastic Utilities Duct for Underground Installation
            Standards Publication

            Fittings for Polyvinyl Chloride (PVC) Plastic Utilities Duct for Underground Installation

            NEMA TC 9-2020 | Status: Active | ID: 100068

            Defines general requirements, including materials, trade sizes, dimensions and workmanship for the following types of fittings for PVC plastic utilities duct used for underground installation of communications and electrical wire and cable: EB, designed for encased burial in concrete when installed in trenches underground, and DB, designed for direct burial in trenches underground without a requirement for encasement in concrete.
            Buy

            Published Date: May.19.2020

            Number of pages: 17

            Staff Contact: Casey Granata

            Download Standard

            Terms & Conditions
            To display, copy and/or download a copy of the document you have requested, NEMA's permission is subject to the following terms and conditions, which you must agree to by clicking on the "I Accept" button below:

            1. I agree not to alter the publication in any way and agree not to change its electronic format.
            2. I agree not to sell or offer for sale the publication for a price or any other consideration.
            3. I agree not to display the publication on a public website or distribute the publication from a public website.
            4. I acknowledge that the copyright to this document belongs to the National Electrical Manufacturers Association (NEMA), and that said copyright owner may revoke its permission or modify any of the foregoing terms and conditions at any time.
            5. I have read NEMA's  Privacy Policy and voluntarily consent to the collection, storage, and use of my personal data provided to NEMA as described in the Privacy Policy.

            Complementary Documents

            standard document

            NEMA TC 9-2020 contents and scope

            ( 148 KB )

            Related Publications

            Standard

            Standards Publication

            NEMA PRP 2-2014 (2019)

            Guidelines for Solvent-Cementing Joints for PVC Rigid Nonmetallic Conduit, Duct, and Fittings

            Standard

            Standards Publication

            NEMA PRP 3-2009 (R2016, R2020)

            Expansion Epoxy-Based Fittings for RTRC Rigid Nonmetallic Conduit

            Standard

            Standards Publication

            NEMA TCB 2-2017

            Guidelines for the Selection and Installation of Underground Nonmetallic Raceways

            Standard

            Standards Publication

            NEMA PRP 4-2009 (R2016)

            Expansion Fittings for Polyvinyl Chloride (PVC) Rigid Nonmetallic Conduit

            Related Products

            Building Infrastructure Image

            Building Infrastructure

            Building Infrastructure Image

            Building Infrastructure

            Keywords

            TC9 TC-9 TC.9 FITTINGS FOR POLYVINYL CHLORIDE (PVC) PLASTIC UTILITIES DUCT FOR UNDERGROUND INSTALLATION TC 9 TC 9-2020

            Topics

            • Polymer Raceway Products
            Contact Us

            Ads

            logo
            • Facebook fb-icon
            • Twitter twitter-icon
            • Blog bing-icon
            • YouTube youtube-icon
            • Podcast rss-icon
            • LinkedIn linkedin-icon
            • About
            • Membership
            • Advocacy
            • Intelligence
            • MITA
            • News & Trends
            • Standards
            • Store
            Information
            Contact Us
            Home
            Privacy Policy
            Site Map
            Terms & Conditions
            Quick Links
            Environmental Stewardship
            Field Representative Program
            Find a Manufacturer
            Find a Standard
            High Performance Buildings Initiative
            NEMA Staff Login
            Intelligence Portal
            International Activities
            NEMA Membership Inquiry
            MyNEMA
            NEMA Premium