# This is a Revit shared parameter file. # Do not edit manually. *META VERSION MINVERSION META 2 1 *GROUP ID NAME GROUP 1 Electrical - Loads GROUP 2 Analysis Results GROUP 3 Analytical Alignment GROUP 4 Analytical Model GROUP 5 Constraints GROUP 6 Construction GROUP 7 Data GROUP 8 Dimensions GROUP 9 Division Geometry GROUP 10 Electrical GROUP 11 Electrical - Circuiting GROUP 12 Electrical - Lighting GROUP 13 Electrical Engineering GROUP 14 Energy Analysis GROUP 15 Fire Protection GROUP 16 General GROUP 17 Graphics GROUP 18 Green Building Properties GROUP 19 Identity Data GROUP 20 IFC Parameters GROUP 21 Layers GROUP 22 Materials and Finishes GROUP 23 Mechanical GROUP 24 Mechanical - Flow GROUP 25 Mechanical - Loads GROUP 26 Model Properties GROUP 27 Other GROUP 28 Overall Legend GROUP 29 Phasing GROUP 30 Photometrics GROUP 31 Plumbing GROUP 32 Rebar Set GROUP 33 Segments and Fittings GROUP 34 Slab Shape Edit GROUP 35 Structural GROUP 36 Structural Analysis GROUP 37 Text GROUP 38 Title Text GROUP 39 Visibility *PARAM GUID NAME DATATYPE DATACATEGORY GROUP VISIBLE DESCRIPTION USERMODIFIABLE HIDEWHENNOVALUE PARAM ba9d2d56-d16f-4ae0-8d98-27457a2f3eb6 Additional Features TEXT 16 1 Specification of additional features, functions, or equipment. 1 PARAM f76afa9e-cd79-4cc4-a39e-b5fa6688d943 Apparent Power Load ELECTRICAL_APPARENT_POWER 1 1 Device or equipment load (not rated power or power rating) 1 PARAM a58a4a05-8c48-42fc-b556-31ecc28b0a3e Apparent Power Per Length ELECTRICAL_APPARENT_POWER 1 1 1 PARAM 1fc4f4a3-5b5f-49bc-91e9-d7d4d6ce7119 Apparent Power Rating ELECTRICAL_APPARENT_POWER 13 1 Apparent power rating of equipment or rated apparent load (not actual load power) 1 PARAM 7226bdbb-c84f-483f-a80b-029dc770ab37 Average Annual Energy Use HVAC_ENERGY 14 1 1 PARAM fe52931c-d64d-4cb0-801f-d323a6742d02 Average Annual Operating Cost CURRENCY 14 1 1 PARAM 9c963503-5d77-4daa-a99d-b792b49bd0c5 Back Installation Clearance LENGTH 8 1 Depth of manufacturer-required clearance for operation, maintenance, or installation. 1 PARAM 215f54a0-e23e-4b3e-80f1-c186c586cb6e Ballast/Driver TEXT 12 1 1 PARAM 661b6bcc-96ee-4a35-9c2d-1aa551071d49 Bottom Installation Clearance LENGTH 8 1 Depth of manufacturer-required clearance for operation, maintenance, or installation. 1 PARAM ebeb432c-bb38-442e-b43d-af4bef237e68 Breaker Positions INTEGER 11 1 Number of single-pole breaker positions available for distribution equipment 1 PARAM f7178ba9-536c-4e6f-87d7-03de5d4bf781 CCT COLOR_TEMPERATURE 12 1 Correlated Color Temperature 1 PARAM 77309beb-3437-4a65-998f-1ab2f0287a13 Certifications TEXT 7 1 Nationally Recognized Testing Laboratory certifications, approvals, or listings. 1 PARAM b4bc36b6-e7fb-41f7-b941-f11c26390ef1 Conductor Material TEXT 13 1 Conductor or bus material (i.e. Copper or Aluminum) 1 PARAM 710af2ed-8c23-4861-9a77-24c7dc7a17f9 Conduit Size CONDUIT_SIZE 13 1 Nominal conduit size 1 PARAM ffc78103-ce36-4051-932e-fd0e3033707a CRI INTEGER 12 1 Color Rendering Index 1 PARAM 2ae60ae0-baaf-4157-b40c-cdfbc1f6081e Current Load ELECTRICAL_CURRENT 1 1 Device or equipment current draw/load (not rated current or current rating) 1 PARAM d699dc0c-baff-43fc-b14f-df50a919377a Current Rating ELECTRICAL_CURRENT 13 1 Current rating of equipment or rated current of load (not actual load current) 1 PARAM bdedad0d-3661-4878-9a5e-fa835b561973 Direct Luminous Flux ELECTRICAL_LUMINOUS_FLUX 12 1 Direct (typically downward) component of total lighting fixture luminous flux 1 PARAM 879fcb73-6326-4a82-826e-0dce2a6dcefe Efficiency Rating NUMBER 14 1 1 PARAM 38862638-72cf-4e17-a5ad-0a830809feef Emergency Component TEXT 12 1 Emergency component (e.g. dual-feed or battery backup) 1 PARAM 9cfefef9-0589-486e-8f2a-29fa65cbf4f7 Emergency Luminous Flux ELECTRICAL_LUMINOUS_FLUX 12 1 Lighting fixture luminous flux when operating in emergency mode. 1 PARAM e2be32e5-bb0d-463d-816b-e833d2cf0fd9 Enclosure Type TEXT 16 1 1 PARAM 0325b2fd-8877-4530-9a2d-0d8d9c862696 Family Creator TEXT 19 1 Creator, author, or developer of family. 1 PARAM ca2eb4e6-49c5-494f-bff5-83b8ab60e8cb Family Version TEXT 19 1 1 PARAM ade1bf01-f266-4837-93eb-90e0d5c54683 Feed-Thru Lugs YESNO 11 1 1 PARAM 58137798-d6ae-4665-a352-b397de55feb5 Finish Description TEXT 22 1 1 PARAM 8bd4dbf3-cc27-479a-ba3d-6c65a83e51f8 FLA ELECTRICAL_CURRENT 1 1 Full Load Amps 1 PARAM 6d442210-1d33-4c73-b919-1988eb5ed4cd Frequency Rating ELECTRICAL_FREQUENCY 13 1 1 PARAM 2464cac2-0326-42e6-ae00-ec45400cb455 Front Installation Clearance LENGTH 8 1 Depth of manufacturer-required clearance for operation, maintenance, or installation. 1 PARAM d277e513-3f1d-43f5-9a60-d6d66eecd3e1 Identity Label TEXT 19 1 Value or designator do identify the equipment. Typically used within tags. 1 PARAM 17d24486-5e8a-4789-90f1-2e440670f099 Identity Mark TEXT 19 1 Identification for individual piece of equipment. 1 PARAM 35874055-1110-4ec7-86b6-c291d69a2346 Identity Type Mark TEXT 19 1 Identification for type of equipment. 1 PARAM 22cd0f44-93fd-4d37-a2bf-6b4a157f1d05 Indirect Luminous Flux ELECTRICAL_LUMINOUS_FLUX 12 1 Indirect (typically upward) component of total lighting fixture luminous flux. 1 PARAM b6e6c45a-ee18-4e12-a9e2-1883b740ce16 Installation Clearance Material MATERIAL 22 1 Material of manufacturer-required operation, maintenance, or installation clearance. 1 PARAM 7abe34ef-0c49-4b87-b854-6f93a9d5ae3b Installation Clearance Visible YESNO 8 1 Visibility of manufacturer-required operation, maintenance, or installation clearance. 1 PARAM d2295584-f96c-462b-bffb-f384f3e0ce49 Installation Type TEXT 16 1 Installation or mounting type or method (e.g. surface, flush, suspended). 1 PARAM 01d8c0ff-b2c0-4102-ba0d-85c6605e7335 Insulation Class TEXT 13 1 1 PARAM ddfc2048-1210-46e5-bdd7-4ebb969042a8 K-Factor TEXT 13 1 K-factor of transformer 1 PARAM 645a1d97-cd6f-4820-b1b4-ebe20ffe0e9c Lamp Quantity INTEGER 12 1 1 PARAM 3cd5049e-0b1e-4cd7-963c-6a59f1b87ee4 Lamp Type TEXT 12 1 1 PARAM c6908b27-af10-479d-8509-6b243b362d40 Left Installation Clearance LENGTH 8 1 Depth of manufacturer-required clearance for operation, maintenance, or installation. 1 PARAM 7ba8f720-3738-4128-9a84-371d793f5807 Lens/Louver TEXT 12 1 1 PARAM dd00796d-b0ce-4bba-aec3-94a90180fb10 Lighting Efficacy ELECTRICAL_EFFICACY 12 1 1 PARAM bdff3eef-d70e-49fb-b831-290a1eaa3d9a Load Classification LOADCLASSIFICATION 1 1 1 PARAM f15b6348-d03e-42dd-bf4f-4d4a31cd7a74 Mains Position TEXT 11 1 Position of the incoming mains (e.g. Top or Bottom), independent of Feed direction. 1 PARAM bbf8ad05-f15d-48a9-b72d-03c7a7241389 Material Description TEXT 22 1 1 PARAM 9a890429-e1ae-45f8-85e7-8c31bfd60f4e Max Ambient Temperature HVAC_TEMPERATURE 14 1 Maximum Ambient Temperature 1 PARAM 365a69eb-e30b-4c11-b704-0d71e065e941 MCA ELECTRICAL_CURRENT 1 1 Minimum Circuit Ampacity 1 PARAM 026ff3f9-477f-42d4-8fe3-ea8a992e1274 Min Ambient Temperature HVAC_TEMPERATURE 14 1 Minimum Ambient Temperature 1 PARAM a4b0bf77-7d8d-4473-83d2-9928bcf3b99c Model Number TEXT 19 1 1 PARAM b38a9c58-5652-4b3a-9da7-c2503061400e Motor Power ELECTRICAL_POWER 1 1 1 PARAM bf293b30-6245-4657-8e0a-d0e288fa874c Neutral Type TEXT 11 1 Displays in panel schedules. 1 PARAM 97cb6676-0239-49c3-9a6a-7854ab0c8a4b Number of Poles NOOFPOLES 13 1 Number of poles of rated and system voltage 1 PARAM 549dad07-ee9e-4a1b-807f-ae5e025c23a0 Percent Impedance ELECTRICAL_DEMAND_FACTOR 13 1 %Z or %IZ 1 PARAM 378385af-d983-4970-a6d2-f3cafde53e9b Phase INTEGER 13 1 Phase of voltage (not construction phase) 1 PARAM 0b538507-88db-4d93-9a9c-6903adcc42a6 Power Factor NUMBER 1 1 1 PARAM 5c5d715b-76aa-490c-8605-48838468ec44 Power Factor State TEXT 1 1 Power factor state of load (leading vs. lagging) 1 PARAM d947aee0-f37b-4dc7-bea8-5c40f132b182 Product Datasheet URL URL 7 1 1 PARAM 038052b7-7d2c-45e2-981f-7dc0b042c255 Product Depth LENGTH 8 1 1 PARAM c59a50f1-6e72-4981-ad58-2a65b8fbc846 Product Diameter LENGTH 8 1 1 PARAM 8822b540-105f-47d1-847d-e3df372faa1e Product Height LENGTH 8 1 1 PARAM 22609487-15f3-4515-8083-d818c1c6a96b Product Installation Manual URL URL 7 1 1 PARAM 51782a3a-e0cb-45b4-86b1-2788dd5d6148 Product Length LENGTH 8 1 1 PARAM 07d7eff8-4273-4ac6-8940-a2d496898ac9 Product Material MATERIAL 22 1 1 PARAM 6195dc41-56aa-4b8b-8a3f-391a04cbd9c3 Product Operation Manual URL URL 7 1 1 PARAM c5f25d97-91ad-48c8-96e2-99eac6fbb3f1 Product Page URL URL 7 1 1 PARAM 73912b3d-aeac-4142-b464-9eaa1037ba1d Product Size TEXT 8 1 1 PARAM 3d8b2540-c18e-40d9-8040-5794128214c1 Product Type TEXT 19 1 1 PARAM 48a78f76-f2fd-4595-a989-e14a6c12735d Product Volume VOLUME 8 1 1 PARAM 4c6b9b09-4acf-401b-9095-e282ea2ecb39 Product Weight WEIGHT 8 1 1 PARAM b3d433e9-f085-469f-810a-ead142e20f7e Product Width LENGTH 8 1 1 PARAM 1c639aca-6ffa-4efc-924d-e8d85195d7d2 Projected Life TIMEINTERVAL 12 1 1 PARAM 4f5e6cd1-be00-4c9c-aab2-53509c99b456 Rated Voltage ELECTRICAL_POTENTIAL 13 1 Nameplate voltage or rated voltage (not System Voltage) 1 PARAM aeb543c7-2ba8-4150-a50a-8eb071687331 Real Power Load ELECTRICAL_WATTAGE 1 1 Device or equipment real power load (not rated power or power rating) 1 PARAM efc15cba-ca9b-473a-90d4-bc6db4d53ecf Real Power Per Length ELECTRICAL_WATTAGE 1 1 1 PARAM 16185ff5-b938-47f5-b1e6-93424ac63124 Real Power Rating ELECTRICAL_WATTAGE 13 1 Real power rating of equipment or rated power of load (not actual load power) 1 PARAM bdabe7a8-f296-4d02-8efd-9b44303fa59d Right Installation Clearance LENGTH 8 1 Depth of manufacturer-required clearance for operation, maintenance, or installation. 1 PARAM c3ec6273-9cd1-4f51-8a53-bbd7b8c2977e SCCR/AIC ELECTRICAL_CURRENT 11 1 Short-Circuit Current Rating, Withstand, or Available Inturrupting Capactiy 1 PARAM b0c82058-e69c-49c4-ae5d-0b30a964a18f Schedule Filter TEXT 19 1 1 PARAM 2e8bbba2-1bd4-4897-bf06-901613c46a19 Schedule Notes TEXT 19 1 1 PARAM 2596c165-d18d-4a10-a737-7dc12074af15 Secondary Current Rating ELECTRICAL_CURRENT 13 1 1 PARAM 691955dc-c34a-40d8-bdb3-7312f99a916c Secondary Voltage Rating ELECTRICAL_POTENTIAL 13 1 1 PARAM cdafdf06-7a58-4c1f-820f-264a9d5af216 Serial Number TEXT 19 1 1 PARAM 60f934b2-40bb-4f75-bf72-3258f543a464 Service Life TIMEINTERVAL 16 1 1 PARAM 87f94314-ba1f-4aee-b234-508eb693941d System Voltage ELECTRICAL_POTENTIAL 13 1 Connected voltage or voltage of electrical system (not Rated Voltage) 1 PARAM ecae99b2-5d2e-4ec2-87d1-fd23f5b52286 Temperature Rise ELECTRICAL_TEMPERATURE 13 1 1 PARAM becb1d0e-2e31-44ca-a551-fcf902f8a79f Top Installation Clearance LENGTH 8 1 Depth of manufacturer-required clearance for operation, maintenance, or installation. 1 PARAM 9900ae7a-6819-4489-bd48-9f8a492f839c X/R Ratio NUMBER 13 1 1 ਍