feature story
Smart Windows:
Energy Efficiency with a View
 |
| NREL research scientist Dane Gillaspie holds a sample of an electrochromic, or color-changing, window inside an accelerated weathering chamber at the Field Test Laboratory Building. Prototype windows are subjected to extreme simulated conditions to determine their performance and durability. |
Imagine wrapping a giant pair of Wayfarers or Aviators around your house on a sunny day. Wouldn't that be cool?
National Renewable Energy Laboratory (NREL) researchers are trying to do the high-tech equivalent of putting sunglasses on buildings with a new generation of insulated "dynamic windows" that change color to modulate interior temperatures and lighting.
Buildings consume 40 percent of the nearly 100 quadrillion Btus (quads) of energy the United States consumes annually. Conventional clear windows account for about one-tenth of the buildings' share of that energy load, or four quads. That's because they allow heat to leak out on chilly days or allow the incoming sun to warm a room to uncomfortable levels, and a building's climate system struggles to adjust.
Using dynamic windows to compensate for some of the electric lighting used inside buildings could save a quad of energy, according to NREL research scientist Dane Gillaspie.
"Combined, a broad installation of these highly insulating, color-changing windows could save about one-eighth of all the energy used by buildings in the U.S. every year, and about 5 percent of the nation's total energy budget," Gillaspie said.
 |
| NREL research scientists Dane Gillaspie and Erin Whitney position an electrochromic window inside a weathering chamber. Samples are performance-tested for 20,000 cycles to simulate 20 years of exposure to heat, humidity, and other conditions. |
Torture Tested
Color-changing windows have been available for more than two decades. While they have attracted widespread interest—NREL provided a prototype in 1998 for a solar home exhibit at Walt Disney's Epcot Center—they have not become widely available or commercially successful.
Since the 1980s, NREL has tested various window technologies and helped establish technical standards for the industry with the American Society for Testing and Materials.
Researchers put window samples into accelerated weathering chambers for 20,000 light-dark cycles, or the equivalent of 20 years of service. Conditions inside the chamber are calibrated at the intensity of one sun (or the amount of light that typically hits Earth on a sunny day) and 176 degrees F (80 degrees C.)
"We call it our torture chamber," said Erin Whitney, NREL's dynamic window testing coordinator.
Many products and prototypes tested in the NREL chamber have performed poorly and their color-changing properties degraded sooner than expected. NREL has verified the performance of one technology developed by Sage Electrochromics, which has a cooperative research agreement with the Laboratory. Sage predicts its technology will drop in price by as much as 70 percent over the next five years as performance improves, volume increases, and production becomes more efficient.
However, today's dynamic windows still cost up to $1,000 per square meter of glass.
"That's a problem," said NREL senior scientist Anne Dillon, who manages the dynamic windows program. "They are too expensive."
 |
| NREL research scientist Robert Tenent manipulates an ink-jet sprayer in a glove box at the Process Development Integration Laboratory. Tenent is incorporating thin-film design and manufacturing processes to improve the performance and lower the cost of electrochromatic windows. |
How They Work
Insulated windows are made from multiple layers of glass. Typically, the spaces between the panes are filled with a gas. Electrochromic windows are made with a very thin stack of dynamic materials deposited on the outside pane.
The dynamic portion consists of three layers: active and counter electrodes separated by an ion conductor layer. NREL researchers are experimenting with electrode layers made of nickel and tungsten oxides; the ions are lithium.
The window changes from clear to tinted when a small electric field is applied and the lithium ions move into the working electrode layers. The change can be triggered by sensors in an automated building management system, or by a flick of a switch. Electrochromic windows can block as much as 98 percent of the direct sunlight. Reversing the polarity of the applied voltage causes the ions to migrate back to their original layer, and the glass returns to clear.
Gillaspie said NREL researchers are using metal oxides because light does not degrade them. While current manufacturer warranties typically extend for 10 years, NREL is aiming to develop windows that perform for 20 years or more.
Although electrochromic windows add yet another powered device to a modern building, they should save far more energy than they consume. Powering 1,500 square feet of color-changing glass (about 100 windows) would require less power than that used by a 75-watt light bulb.
And because the windows modulate the building's interior climate, the rest of the heating, cooling, and illumination systems can be smaller, leading to lower construction costs and lower monthly energy bills.
In computer simulations of building performance, the electrochromic windows:
- reduce electricity consumption for cooling by up to 49 percent;
- lower peak electrical power demand by up to 16 percent; and
- decrease lighting costs by up to 51 percent.
"The brilliant thing is that not only do you save energy with these windows, but they allow you to scale back the HVAC, so you save money," Gillaspie said.
 |
| NREL's electrochromic window research team includes (from left) Robert Tenent, Dane Gillaspie, Erin Whitney, and senior scientist Anne Dillon. |
Learning from Photovoltaics
If the dynamic layers of the electrochromic window remind you of an advanced solar cell, it's no coincidence. The entire dynamic stack between the glass panes measures about a micron thick. That's about the same as thin-film photovoltaic cells.
The dynamic layers of electrochromic windows are manufactured with a vacuum deposition process called "sputtering." The process is also used in PV and semiconductor manufacturing because it provides a high degree of control and creates uniform results when depositing materials in ultrathin coatings. However, sputtering is relatively slow and energy-intensive.
NREL researchers are working to drive down high manufacturing costs by creating the dynamic layers using inexpensive printing technologies and metallic inks similar to research into high-volume thin-film PV manufacturing already taking place at NREL.
NREL's smart window engineers will be using some of the same equipment with window manufacturers in the advanced Science and Technology Facility, including the Atmospheric Processing Platform in the Process Development and Integration Laboratory.
NREL researchers are also investigating ways of rapidly making electrochromic films on cheaper, flexible plastic substrates instead of glass. This will allow development of so-called "roll to roll" (R2R) processing methods similar to those used to print newspapers.
An electrochromic device made of flexible materials could be retrofitted to existing windows, NREL research scientist Robert Tenent said. He added that expanding into the retrofit market would expand the windows' use and accelerate energy savings.
"By and large, high manufacturing costs are limiting the implementation of these dynamic materials," Tenent said. "A significant portion of our research efforts are directly focused on eliminating that expense through manufacturing improvements and allowing us to realize the tremendous potential energy savings that this technology holds."
The PV connection doesn't end there. Dynamic windows are typically hardwired into a building's electrical system. But in a wireless version, the power for the color change could come from a small PV cell installed in the window's casement.
When sunlight hits the PV cell, it converts the sunlight to power, which ionizes the electrode layers and darkens the window.
Eventually, dynamic windows may produce more energy than they consume so power generation would not be limited to a rooftop PV system.
NREL research supports the U.S. Department of Energy's goal of deploying energy-saving windows for residential construction by 2015 and commercial buildings by 2020.
Learn more about DOE's Electrochromic Initiative and Windows Technology program.
Photo Credits: Pat Corkery
We thank you for your cooperation in improving the quality of our materials.
Please contact Bill Green at Communications@nema.org if you have any questions or suggestions related to eiXtra. |
 |
Hot Topics |
02.01.10
Smart Grid Could Reduce Emissions by 12 Percent
A smart electrical power grid could decrease annual electric energy use and utility sector carbon emissions at least 12 percent by 2030, according to a new report from the Department of Energy's Pacific Northwest National Laboratory.
02.01.10
Rockwell Automation and Rockwell Collins Sponsor FIRST® Interactive Robotics Station in the Automation Federation’s Boy Scout Jamboree 2010 Exhibit
The Automation Federation (AF) announced that Rockwell Automation and Rockwell Collins will participate in the AF Technology Quest exhibit at the 2010 Boy Scout Jamboree, which will be held July 26 through August 4, 2010, at Fort A.P. Hill, Virginia.
02.01.10
Osram Sylvania’s Socket Survey Reveals Gaps between Awareness and Adoption of Green Lighting Technology
The second annual Sylvania Socket Survey reveals a paradox in Americans' attitudes towards lighting—while 74 percent have switched to an energy-saving light bulb in the past year, the vast majority still don’t know about the impending federal phase-out of incandescent bulbs, starting in 2012 with the 100-watt bulb.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
 |
On the Hill/Around the Nation |
01.21.10
Wind for Schools Program Adds Funding in Five States
Universities in Alaska, Arizona, Pennsylvania, North Carolina, and Virginia to lead projects
The U.S. Department of Energy’s (DOE) National Renewable Energy Laboratory (NREL) and DOE’s Wind and Hydropower Technologies Program announced the selection of five additional states to each receive approximately $60,000 in funding per year for three years for activities supporting Wind Powering America's Wind for Schools project.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
 |
International News |
01.27.10
The eThekwini Landfill Gas CDM Project Launches on Schedule
The second component of the eThekwini Durban landfill gas to electricity Clean Development Mechanism (CDM) project was launched by South Africa's Energy Minister Dipuo Peters on January 27, 2010.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
 |
NEMAVoice |
Industry News
Contracts
- Itron Awarded AMR Water Contract in India
Itron Inc. announced that it has been awarded a contract for the delivery of a complete remote meter reading system with 150,000 Automated Meter Reading (AMR) water meters to the Municipal Corporation of Greater Mumbai (MCGM) in India. 01/26/10
- GE, Nuclearelectrica Sign Agreement Valued at up to $146 Million
GE and Nuclearelectrica, Romania’s state-owned nuclear utility, have signed a services and maintenance agreement for the Cernavoda Nuclear Power Plant (NPP), valued at up to $146 million. 01/22/10
Mergers & Acquisitions
- Thomas & Betts to Acquire JT Packard & Associates
Thomas & Betts Corporation announced that it has agreed to acquire the net assets of JT Packard & Associates, Inc., a service provider of power equipment used by industrial and commercial enterprises. 01/21/10
Personnel
[ Industry News Archives ]
NEMA News
- MITA Statement on Medical Radiation
The Medical Imaging & Technology Alliance (MITA) issued statements regarding The New York Times' series of articles examining the use of medical radiation and the new technologies that deliver it. 01/28/10
- NGLIA Members Receive DOE Awards to Develop LED Technology and Manufacturing
NEMA has announced that six member companies of the Next Generation Lighting Industry Alliance (NGLIA) have been awarded nine projects by the U.S. Department of Energy to spur development of solid-state lighting (SSL) technology, which uses light-emitting diode (LEDs) and organic LEDs. 01/25/10
- NEMA Director Named to NIST Governing Board of Smart Grid Standards Panel
NEMA has announced that John F. Caskey, senior director of its Power Equipment Division, has been named vice chair of the Governing Board of the Smart Grid Interoperability Panel (SGIP) of the National Institute of Standards and Technology (NIST). 01/20/10
Standardizations Trends
[ NEMA News Archives ]
NEMA/BIS
 |
Market Comments by Tom Robinson
Last week markets around the world declined. Tech stocks were a key element, but many Asian markets were particularly hard hit on issues about the pace of Chinese growth, among other things. read more... |
| Register for upcoming NEMA events: |
|
|
To view this email on the web, go to http://www.nema.org/media/eiextra/briefs/20100201eiXtra.htm
|